Home › Furnace blowing cold air
Furnace Blowing Cold Air: Causes and What to Check
Some links on this page are affiliate links. If you buy through them we may earn a commission at no extra cost to you. How we make money.
Why the air can be cold
ServiceMag describes several patterns:
| What you notice | Possible cause (ServiceMag) |
|---|---|
| Burners run a few minutes, shut off, blower keeps going | Too little air crossing the heat exchanger. The high-limit switch tripped. Dirty filter, closed or blocked registers or a blocked return are common. |
| Burners light, then drop out within seconds and retry | Flame sensing failure (such as a coated flame sensor). A technician cleans and tests it. |
| High-efficiency (90%+) furnace never lights | A blocked condensate drain can back water up into the pressure switch tubing. |
| Dense new filter, then problems start | A dense 1-inch pleated filter can restrict airflow enough to trigger limit trips. |
Source: ServiceMag, Furnace Short Cycling. These are patterns, not a diagnosis.
What you can check
- The filter. Replace a dirty one and make sure it is seated correctly and not doubled up in one slot (ServiceMag). See the filter guide.
- Registers and returns. Open closed registers and clear furniture from return grilles (ServiceMag).
- The thermostat. Make sure it is set to heat. ServiceMag says a thermostat in direct sun, above a register or on an exterior wall can satisfy too quickly.
What to leave to a pro
ServiceMag lists limit switch testing, flame sensor cleaning and microamp measurement, inducer and pressure switch diagnosis, and reading the board's fault code as pro work. Do not open the burner area.
Call the same day if
- The furnace cycles and blows cold air (ServiceMag).
- There is soot or scorching near the burners (ServiceMag).
- A CO alarm has ever gone off (ServiceMag). If one is sounding now, leave and call 911.
Need a new filter?
Match the size printed on the old filter's frame. Check your furnace manual before choosing a high MERV rating.
How to change itSee furnace filtersChecks did not fix it?
Gas, burner, ignition and venting problems are for a licensed HVAC technician. Our guide covers which signs mean call now.
When to call an HVAC technicianFind a licensed HVAC pro near youCommon questions
Why is my furnace blowing cold air?
ServiceMag says the burners may not be lighting, may drop out within seconds (flame sensing), or may shut off after a few minutes because airflow is too low, with the blower still running.
Can a dirty filter make a furnace blow cold air?
It can contribute. ServiceMag says a dirty filter is a common cause of the high-limit trip, which shuts the burners while the blower keeps running.
When should I call for service?
ServiceMag says to call the same day if the furnace cycles and blows cold air, or if there is soot or scorching near the burners.